Jameco-electronics Rabbit 3000 Manual de usuario Pagina 230

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 349
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 229
Users Manual 221
The required memory output enable access time is more complicated since it is affected by
the clock doubler delays. The clock doubler setup register creates a nominal delay time
ranging from 6 to 20 ns, resulting in a nominal clock low time ranging from 6 to 20 ns.
The clock low time depends on internal delays, and is subject to variation arising from
process variation, operating voltage and temperature. Minimum and maximum clock low
times for various doubler settings are given in the formulas and in the graph below.
Max. delay @ 3.3 V = 6.1 + 1.21(n - 6) [n is the nominal delay, 6–20 ns)
Min. delay @ 3.3 V = 3.7 + 0.75(n - 6)
Max. delay @ 2.5 V = 7.6 + 1.67(n - 6)
Min. delay @ 2.5 V = 4.7 + 1.03(n - 6)
Max. delay @ 1.8 V = 12.2 + 2.7(n - 6)
Min. delay @ 1.8 V = 6.6 + 1.44(n - 6)
Figure 16-5. Clock Doubler Max-Min Clock Low Times
0.0
10.0
20.0
30.0
40.0
50.0
60.0
0 5 10 15 20 25
Nominal Delay (ns)
Delay (ns)
3.3 V
2.5 V
1.8 V
Vista de pagina 229
1 2 ... 225 226 227 228 229 230 231 232 233 234 235 ... 348 349

Comentarios a estos manuales